This image is representative of the product and may not be the exact image of this product.
| Model: ACE-723C |
Manufacturer: IEI | Rugged 230W/+24VDC Input Power Supply |
Product Status: Discontinued - This product is no longer in production. This page is maintained for informational purposes only. Stock Status: Not Available |
|
|
|
|
Input Table :
Model |
Input Range |
Input Current |
ACE-723A |
85 ~ 135V AC or 180 ~ 265V AC,
47 ~ 440Hz |
5A@115V AC or 3A@230V AC |
ACE-723B |
85 ~ 135V AC or 180 ~ 265V AC,
47 ~ 440Hz |
5A@115V AC or 3A@230V AC |
ACE-723T |
-36 ~ 72V DC |
8A@-48V DC |
ACE-723C |
+19 ~ +30V DC |
16A@+25V DC |
- Output Table ( at 40oC ) :
Model |
Rated Load |
Max. Output |
+5V |
+12V |
-5V |
-12V |
+24V |
+5V |
+12V |
-5V |
-12V |
+24V |
ACE-723A |
20A |
6A |
1A |
1A |
|
33A |
12A |
1.5A |
1.5A |
|
ACE-723B |
21A |
5A |
|
1A |
1A |
33A |
12A |
|
1.5A |
1.5A |
ACE-723T |
22A |
6A |
1A |
1A |
|
33A |
12A |
1.5A |
1.5A |
|
ACE-723C |
22A |
6A |
1A |
1A |
|
33A |
12A |
1.5A |
1.5A |
|
- Inrush Current (
ACE-723A/B ) : Not exceed 15A@115V AC or 30A @230V AC
- Ripple and Noise :
Less than 100mV
- Line Regulation :
The line regulation for each outputs are less than +/-1%, while measuring at rated loading and +/-10% of input voltage changing
- Load Regulation :
Less than +/-1%@+/-5V and -12V, +/-4%@+12V and +24V ( ACE-723B )
- Efficiency :
Higher than 75%
- Hold-up Time ( ACE-723A/B ) :
20ms (typical)@115V AC
- Protection :
Over voltage protection. The trip point is around 5.9V ~ 7.0V output
- Thermal Protection :
Built in 110+/-5oC thermal switch in HS1
- Altitude :
0 ~ 10,000ft
- Vibration :
10 ~ 55Hz at 2G 3min. period, 30min. along X, Y and Z axis
- Impact :
10G for 20ms once on each X, Y and Z axis
- Hi-port isolation :
--> 4300V DC, input to output for one minute
--> 2200V DC, input to ground for one minute
- MTBF :
--> ACE-723A : 206,500 Hours
--> ACE-723B : 206,300 Hours
--> ACE-723T : 206,700 Hours
--> ACE-723C : 205,900 Hours
- Safety :
Meets UL 478, 1012, 1950; CSA 22.2 No. 234, VDE EN 60 950
- EMI :
Meets FCC docket 20780 curve "A", EN50081-2 : CISPR22 "A"
- EMS Standard ( Design to meet the following limits ) :
--> EN 50082-2
--> IEC 801-1 8KV (Air Discharge ) criteria B
--> IEC 801-3, 10V/M criteria A
--> IEC 801-4, 2KV criteria B
--> IEC 801-5, 2KV criteria B
- Built-in ball bearing cooling fan
- Operating Temperature :
-20o ~ 70oC ( Derating curve will occur 50o ~ 70oC)
- Storage Temperature :
-20o ~ 85oC
- Dimensions :
112(W) x 51(H) x 203(D)mm; ( 4.4" x 2" x 8" )
|
| More Info |
|
|
|
|
|
|
|