SDX-300-24
Input
Max. Current
19V ~32V
26A


DC Output Characteristics
Output Volt.
V1
V2
V3
V4
V5
V6
+3.3V
+5V
+12V
-5V
-12V
+5Vsb
Min. Load
0.2A
2A
0.5A
0A
0A
0A
Max. Load
25A
30A
12A
8A
2.7A
1A
Max. Output
V1 & V2 total output max. 150 watts
All output max. 300 watts
Regulation
±5%
±5%
±5%
±5%
+10/-8%
±5%
Ripple & Noise(max.)
50mV
60mV
120mV
70mV
180mV
50mV
OVP (Trigger point)
+3.3V : +3.8V ~ +4.5V
+5V : +5.8~+6.8V
  +12V : +13.8 ~ 16.2V
Efficiency(min.)
64%


Rise time: 60ms. max.
Power good signal: Power on within 100~500ms
High level TTL signal release
Operating temperature: 0~70°C (32 to 157°F),
De-rating factor 45°C ~70°C : 2.5% / °C
Operating humidity: 20% ~ 85%RH. Non-Condensing
Storage and Shipping: 10% ~ 95%RH. Non-Condensing
Safety standard: Meet
UL 1950
cUL
TUV EN60950
CB
Packing: NW: 3.74Lb (1.7kg) / 1PCS
GW: 4.18Lb (1.9kg) / IPCS
10 PCS / 1CTN. NW / GW. 17kg /19kg CUFT:2.055