This image is representative of the product and may not be the exact image of this product.
| Model: ACE-832A/832AP |
Manufacturer: ICP | 300W ATX Power Supplies |
Product Status: Discontinued - This product is no longer in production. This page is maintained for informational purposes only. Stock Status: Not Available |
|
|
|
|
● Input: 90V-264VAC (ACE-832AP)
● Input: 90V-264VAC (ACE-832AP)
95V-132VAC,180-264VAC auto-range (ACE-832A)
● ACE-832A/832AP Output Rating
Output |
Nomial |
Regulation |
Ripple/Noice |
Min. |
Max. |
1 |
+3.3V |
+/- 5% |
50mV |
0.3A |
28A |
2 |
+5V |
+/- 5% |
50mV |
0.1A |
30A |
3 |
+12V |
+/- 5% |
120mv |
0.1A |
15A |
4 |
-5V |
+/- 5% |
100mV |
0A |
0.3A |
5 |
-12V |
+/- 5% |
120mV |
0A |
0.8A |
6 |
+5VSB |
+/- 5% |
100mV |
0A |
2.0A |
Total Output of +3.3V and +5V shall not exceed 150W.
+3.3V, +5V, and +12V total ouput power max. is 280W.
● |
Hold-up time : |
17ms min |
● |
Efficiency: |
65% typ |
● |
Protection: |
Over Voltage/Load Protection and Short Circuit Protection |
● |
TTL signal compatible power good signal |
● |
Vibration: |
10-55 Hz at 2G 3min. period, 30 min. along X,Y and Z axis. |
● |
Shock: |
10G for 11ms once on each X, Y and Z axis. |
● |
Built-in cooling fan |
● |
MTBF |
min. 50,000hrs at 25 oC |
● |
Safety: |
Meets UL 1950, CSA 22.2 Level 3, TUV or VDE,NEMKO, CE |
● |
EMI: |
Meets FCC class "B", EN55022 class "B" |
|
|
Meets Harmonic EN61000-3-2 (ACE-832AP) |
● |
EMS Standard : meet |
- IEC 801-2 8KV(Air Discharge)
- IEC 801-3 3V/M criteria A |
|
|
- IEC 801-4, 2KV criteria B
- IEC 801-5, 2KV criteria B |
● |
Operating Temp.: |
0-50 oC |
|
|
|
|
|
|