ACE-855/845
ACE-855/845 Image
This image is representative of the product and may not be the exact image of this product.
Model: ACE-855/845
Manufacturer: ICP
AC/DC Input LCD Panel PC 55W Power Supply
Product Status: Discontinued - This product is no longer in production. This page is maintained for informational purposes only.

Stock Status: Not Available

 
n Input Table:
  • Input Table:

Model

Input Voltage

Input Current

ACE-855A

85 ~ 264V AC,47 ~ 63Hz

2A@115V AC or 1A@230V AC

ACE-855C

+16 ~ +32V DC

9A@+16V DC

ACE-845V

+9.5 ~ +18V DC

10A@+9.5V DC

  • Output Table: (at 50 oC):

Model

Rated Load

Max. Output

+5V

+12V

+5V

+12V

ACE-855A

8A

1.2A

10A

4A

ACE-855C

8A

1.2A

10A

4A

ACE-845V

8A

1.1A

8A

2A

 

  • IInrush Current (ACE-855A)

 

Not exceed 115V@30A AC or 230V AC@60A

  • Ripple and Noise:

Less than 1% of output voltage

  • Line Regulation:

The line regulation for each outputs are less than ±1%, while measuring at rated loading and ±10% of input voltage changing

  • Load Regulation:

Less than ±3%@+5V, ±5%@+12V

  • Efficiency:

Higher than 70%

  • Hold-up Time (ACE-855A):

16ms (typical)@115V AC

  • Altitude:

0 ~ 10,000ft

  • Protection:

Over voltage protection. The trip point is around 5.7V ~ 7.0V output

  • Vibration:

10 ~ 55Hz at 2G 3min. period, 30 min.along X, Y and Z axis

  • Impact:

10G for 20ms once on each X, Y and Z axis

  • MTBF:

--> ACE-855A : 335,874 Hours
--> ACE-855C : 327,482 Hours
--> ACE-845V : 339,662 Hours

  • Safety:

Meets UL 1950; CSA 22.2 No. 234, VDE EN 60 950

  • EMI :

Meets FCC docket 20780 curve "B",

  • EMS Standard (Design to meet the following limits):

- EN 50082-2

- IEC 801-2 8KV (Air Discharge) criteria B

- IEC 801-3, 10V/M criteria B

- IEC 801-4, 2KV criteria B

- IEC 801-5, 2KV criteria B

  • Operating Temperature:

-20 ~ 70oC(Derating curve will occur 50 ~ 70oC)

  • Storage Temperature:

-20 ~ 85oC

  • Dimensions:

50.5(W) X 37 (H) X177.5 (D) mm;(2"× 1.5"× 7")

 